M. Nathan Nair, Rohan Ramakrishna, Jeff Slimp, Gregory Kinney, Randall M. Chesnut


April 2010, Volume 19, Issue 2, pp 203 - 205 Case Report Read Full Article 10.1007/s00586-010-1372-3

First Online: 17 April 2010

Serious vascular injury is a rare, but potentially devastating complication during anterior lumbar spinal surgery. The authors describe the first reported case where vascular injury was detected by multimodality neurophysiological monitoring during an L3–S1 anterior lumbar interbody fusion. The case demonstrates the need for multi-modality monitoring and the combined use of somatosensory-evoked potentials and motor-evoked potentials.